 www.murata-ps.com
PRODUCT OVERVIEW
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Typical unit
FEATURES
Wide 2.4-5.5 VDC input range Non-isolated output adjustable from 0.7525 to 3.63 Volts up to 16 Amps DOSA-compatible SMT package Drives 1000 F ceramic capacitive loads Optional sequence/tracking operation Outstanding thermal performance and derating Short circuit protection On/Off control High efficiency with no heatsink Over temperature protection Designed to meet UL/EN/IEC 60950-1 safety approvals.
The OKY-T/10 and -T/16 series are SMT nonisolated Point-of-Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifications (www.dosapower.com). Applications include powering CPU's, datacom/telecom systems, programmable logic and mixed voltage systems. The wide input range is 2.4 to 5.5 Volts DC. Two maximum output currents are offered, 10 Amps (T/10 models) or 16 Amps (T/16 models). Based on fixed-frequency synchronous buck converter switching topology, the high power conversion
efficient Point of Load (POL) module features programmable output voltage and On/Off control. An optional Sequence/Tracking input allows controlled ramp-up and ramp-down outputs. The Sense input provides remote sense. These converters also include under voltage lock out (UVLO), output short circuit protection, over-current and over temperature protections. These units are designed to meet all standard UL/EN/IEC 60950-1 safety and FCC EMI/RFI emissions certifications and RoHS-6 hazardous substance compliance.
Contents Description, Connection Diagram, Photograph Ordering Guide, Model Numbering Mechanical Specifications, Input/Output Pinout Detailed Electrical Specifications Output Voltage Adjustment, Soldering Guidelines Application Notes Performance Data and Oscillograms - OKY2-T/16-W5 Tape and Reel Information
Page 1 2 3 4 5 6 9 16
Simplified Block Diagram
+Vin F1 +Vout
On/Off Control
Sense Controller
External DC Power Source
Trim Open = On Closed = Off (Positive On/Off) Common Reference and Error Amplifier
Common
Figure 1. OKY-T/10, -T/16
Sequence/Tracking (OKY2 only)
Note: Murata Power Solutions strongly recommends an external input fuse, F1. See specifications.
For full details go to www.murata-ps.com/rohs
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 1 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Performance Specifications and Ordering Guide
ORDERING GUIDE On/Off Polarity Sequence/ Tracking Output VOUT (Volts) 0.7525-3.63 0.7525-3.63 Input Package, C83
Model Number OKY-T/10-W5P-C OKY-T/10-W5N-C
R/N (mVp-p) Regulation (Max.) VIN Efficiency c IOUT IIN, IIN, (Amps Power Nom. Range no load full load max) (Watts) Max. f Line Load (Volts) (Volts) (mA) (Amps) Min. Typ. 10 10 10 10 16 16 16 16 33.0 33.0 33.0 33.0 52.8 52.8 52.8 52.8 20 20 20 20 50 50 50 50 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 1% 1% 1% 1% 1% 1% 1% 1% 5 5 5 5 5 5 5 5 2.4-5.5 2.4-5.5 2.4-5.5 2.4-5.5 2.4-5.5 2.4-5.5 2.4-5.5 2.4-5.5 80 80 80 80 80 80 80 80 7.58 7.58 7.58 7.58 11.12 11.12 11.12 11.12 92% 92% 92% 92% 95% 95% 95% 95%
Case 1.3x0.53x0.33 (33x13.5x8.3) 1.3x0.53x0.33 (33x13.5x8.3) 1.3x0.53x0.33 (33x13.5x8.3) 1.3x0.53x0.33 (33x13.5x8.3) 1.3x0.53x0.33 (33x13.5x8.3) 1.3x0.53x0.33 (33x13.5x8.3) 1.3x0.53x0.33 (33x13.5x8.3) 1.3x0.53x0.33 (33x13.5x8.3)
Pinout P66 P66 P66 P66 P66 P66 P66 P66
Pos. Neg. Pos. Neg. Pos. Neg. Pos. Neg.
No No Yes Yes No No Yes Yes
OKY2-T/10-W5P-C 0.7525-3.63 OKY2-T/10-W5N-C 0.7525-3.63 OKY-T/16-W5P-C OKY-T/16-W5N-C 0.7525-3.63 0.7525-3.63
92.5% 95% 92.5% 95% 92.5% 95% 92.5% 95%
OKY2-T/16-W5P-C 0.7525-3.63 OKY2-T/16-W5N-C 0.7525-3.63

Efficiency is shown at Vout=1V..
All specifications are at nominal line voltage, Vout=nominal (3.3V) and full load, +25 deg.C. unless otherwise noted. Output capacitors are 1 F ceramic and 10 F electrolytic in parallel. Input cap is 22 F. See detailed specifications. I/O caps are necessary for our test equipment and may not be needed for your application.
Use adequate ground plane and copper thickness adjacent to the converter. f Ripple and Noise (R/N) is shown at Vout=1V. See specs for details. g Dimensions are in inches (mm).
PART NUMBER STRUCTURE
OK Y 2 - T / 16 - W5 P - C
Okami Non-isolated PoL Surface Mount Sequence/tracking Blank=Not installed, delete seq/track contact 2=Installed, add seq/track contact Trimmable Output Voltage Range W5 Models = 0.7525-3.63V RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS exemption 7b-lead in solder) On/Off Polarity P = Positive Polarity N = Negative Polarity
Input Voltage Range W5 = 2.4-5.5V
Maximum Rated Output Current in Amps
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 2 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
MECHANICAL SPECIFICATIONS
PIN #1 THIS CORNER (FARSIDE)
TOP VIEW
[13.5] 0.53 REF [12.7] 0.50
ISOMETRIC VIEW
[6.9] 0.27
NOZZLE PICKUP POINT
SIDE VIEW MTG PLANE
[3.05] 0.120 [33.0] 1.30 [19.3] 0.760 REF 4x [4.83] 0.190
[8.4] 0.33
END VIEW
PIN #1 [1.60] 0.063
3 BOTTOM VIEW 2
4
5
6
7
[10.29] 0.405 [13.5] 0.53
[0.64] 0.025
[29.9] 1.177
1
[1.22] 0.048
[1.91] 0.075 [33.0] 1.30 REF [29.9] 1.177 [26.85] 1.057 [22.02] 0.867
[.064] 0.025
[3.05] 0.120 MIN [3.43] 0.135 MAX [1.91] 0.075
[13.5] 0.53 REF [2.41] 0.095 MIN [2.79] 0.110 MAX
2 3 4 56 7
1
[7.54] 0.297 [12.37] 0.487 [17.20] 0.677
[10.29] 0.405
DIMENSIONS ARE IN INCHES [mm] TOLERANCES: x.xxx .02 in. x.xx .010 in. ANGLES: 1
[1.22] 0.048
RECOMMENDED PAD LAYOUT
COMPONENTS SHOWN ARE FOR REFERENCE ONLY MATERIAL: SMT PINS: COPPER ALLOY
THIRD ANGLE PROJECTION
Case C83
I/O CONNECTIONS Pin Function P66 1 On/Off Control * 2 +Vin 3 Vtrack Seq** 4 Gnd (Common) 5 +Vout 6 Trim 7 Sense * The Remote On/Off can be provided with either positive (P suffix) or negative (N suffix) polarity. ** Vtrack Seq applies only to OKY2 models. No connection for OKY models.
FINISH: (ALL PINS) GOLD (5u"MIN) OVER NICKEL (50u" MIN)
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 3 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Performance and Functional Specifications
See Note 1
Input Dynamic Characteristics
Input Voltage Range Isolation Start-Up Voltage Undervoltage Shutdown (see Note 15) Overvoltage Shutdown Reflected (Back) Ripple Current (Note 2) Internal Input Filter Type Recommended External Fuse Reverse Polarity Protection Input Current: Full Load Conditions Inrush Transient Shutdown Mode (Off, UV, OT) Output in Short Circuit Low Line (Vin=Vmin) Remote On/Off Control (Note 5) Negative Logic ("N" model suffix) Current Positive Logic ("P" model suffix)
See Ordering Guide and Note 7. Not isolated 2.05V (OKY-T/16-W5) 1.90 V (OKY-T/16-W5) None 20 mA pk-pk Capacitive 10A ( OKY-T/10-W5) 15A ( OKY-T/16-W5) N/A. See fuse information. See Ordering Guide 0.4 A2Sec. 5 mA 60 mA 5.41A. (OKY-T/10-W5) 14.63A. (OKY-T/16-W5) ON = Open pin or ground to +0.4V. max. OFF = +1.5V min. to +Vin max. 1 mA ON = Open pin (internally pulled up) or +1.5Vdc to +Vin max. OFF = Ground pin to +0.4V. max. 1 mA
Dynamic Load Response 100Sec max. to within 2% of final value (50-100% load step, di/dt = 1A/Sec) with 2 x 150 F polymer external caps. Start-Up Time (Vin on or On/Off to Vout regulated) Switching Frequency 8 mSec for Vout=nominal (Vin On) 6 mSec for Vout=nominal (Remote On/Off) 300 KHz
Environmental
Calculated MTBF Telecordia method (4a) Calculated MTBF MIL-HDBK-217N2 method (4b)
TBD TBD
Operating Temperature Range (Ambient, vertical mount) See derating curves -40 to +85C. with derating (Note 9) Operating PC Board Temperature -40 to +100C. max., no derating (12) Storage Temperature Range -55 to +125 C. Thermal Protection/Shutdown +130C. Relative Humidity to 85%/+85C., non-condensing
Physical
Outline Dimensions Weight Safety Restriction of Hazardous Substances MSL Rating
Current
See Mechanical Specifications 0.1 ounces (2.8 grams) Designed to meet UL/cUL 60950-1, CSAC22.2 No. 60950-1, IEC/EN 60950-1 RoHS-6 (does not claim EU RoHS exemption 7b-lead in solder) 2
Output
Output Power Minimum Loading Accuracy (50% load, untrimmed) Voltage Output Range (Note 13) Overvoltage Protection (Note 16) Temperature Coefficient Ripple/Noise (20 MHz bandwidth) Line/Load Regulation Efficiency Maximum Capacitive Loading (Note 14) Cap-ESR=0.001 to 0.01 Ohms Cap-ESR >0.01 Ohms Current Limit Inception (Note 6) (98% of Vout setting, after warm up) Short Circuit Mode Short Circuit Current Output Protection Method Short Circuit Duration Prebias Startup Tracking/Sequencing Slew Rate Tracking accuracy, rising input Tracking accuracy, falling input
36W (OKY-T/10-W5) 52.8W (OKY-T/16-W5) No minimum load 2 % of Vnominal See Ordering Guide None 0.02% per C of Vout range See Ordering Guide and note 8 See Ordering Guide and note 10 See Ordering Guide 1,000 F 5,000 F (min. cap. load 0 F) 16A ( OKY-T/10-W5) 39A ( OKY-T/16-W5) 1A (OKY-T/10-W5) 2A (OKY-T/16-W5) Hiccup autorecovery upon overload removal. (Note 17) Continuous, no damage (output shorted to ground) Converter will start up if the external output voltage is less than Vnominal. 2 Volts per millisecond, max. Vout = 200 mV max. of Sequence In Vout = 400 mV max. of Sequence In
(1)
Absolute Maximum Ratings
0 V.to +5.8 Volts max. 0 V. min. to +Vin max. See Fuse section Current-limited. Devices can withstand a sustained short circuit without damage. The outputs are not intended to accept appreciable reverse current. Storage Temperature -55 to +125 C. Lead Temperature See soldering specifications Absolute maximums are stress ratings. Exposure of devices to greater than any of any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied or recommended.
Input Voltage (Continuous or transient) On/Off Control Input Reverse Polarity Protection Output Current (Note 7)
Specification Notes:
Specifications are typical at +25 C, Vin=nominal (+5V.), Vout=nominal (+3.3V), full load, external caps and natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced airflow. All models are tested and specified with external 1 F paralleled with 10F ceramic output capacitors and a 22 F external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specified performance in your applications. However, Murata Power Solutions recommends installation of these capacitors. All models are stable and regulate within spec under no-load conditions. (2) (3) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin=2 x 100 F tantalum, Cbus=1000 F electrolytic, Lbus=1 H. Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the Derating curve.
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, Tpcboard=+25 C, full output load, natural air convection. (4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground benign, +25C., full output load, natural convection.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 4 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Specification Notes, Cont.:
(5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which do not exceed +Vin. Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. For W5 models, the Input Voltage must exceed the Output Voltage at all times by 0.5 Volts or greater. Output noise may be further reduced by adding an external filter. At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load. All models are fully operational and meet published specifications, including "cold start" at -40 C.
Soldering Guidelines
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Your production environment may differ therefore please thoroughly review these guidelines with your process engineers.
(6) (7) (8)
(9)
Reflow Solder Operations for surface-mount products (SMT)
(10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. (11) Other input or output voltage ranges will be reviewed under scheduled quantity special order. (12) Maximum PC board temperature is measured with the sensor in the center of the converter. (13) Do not exceed maximum power specifications when adjusting the output trim. (14) The maximum output capacitive loads depend on the the Equivalent Series Resistance (ESR) of the external output capacitor and, to a lesser extent, the distance and series impedance to the load. Larger caps will reduce output noise but may change the transient response. Newer ceramic caps with very low ESR may require lower capacitor values to avoid instability. Thoroughly test your capacitors in the application. Please refer to the Output Capacitive Load Application Note. (15) Do not allow the input voltage to degrade lower than the input undervoltage shutdown voltage at all times. Otherwise, you risk having the converter turn off. The undervoltage shutdown is not latching and will attempt to recover when the input is brought back into normal operating range. (16) The outputs are not intended to sink appreciable reverse current. (17) "Hiccup" overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again. This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal operation.
For Sn/Ag/Cu based solders: Preheat Temperature Time over Liquidus Maximum Peak Temperature Cooling Rate For Sn/Pb based solders: Preheat Temperature Time over Liquidus Maximum Peak Temperature Cooling Rate Less than 1 C. per second 60 to 75 seconds 235 C. Less than 3 C. per second Less than 1 C. per second 45 to 75 seconds 260 C. Less than 3 C. per second
Recommended Lead-free Solder Reflow Profile
250 Peak Temp. 235-260 C
Temperature (C)
Output Voltage Adustment The output voltage may be adjusted over a limited range by connecting an external trim resistor (Rtrim) between the Trim pin and Ground. The Rtrim resistor must be a 1/10 Watt precision metal film type, 1% accuracy or better with low temperature coefficient, 100 ppm/oC. or better. Mount the resistor close to the converter with very short leads or use a surface mount trim resistor. In the tables below, the calculated resistance is given. Do not exceed the specified limits of the output voltage or the converter's maximum power rating when applying these resistors. Also, avoid high noise at the Trim input. However, to prevent instability, you should never connect any capacitors to Trim.
200
150 Soaking Zone 120 sec max 100 <1.5 C/sec 50 240 sec max
Reflow Zone time above 217 C 45-75 sec
Preheating Zone
0 0 30 60 90 120 150 Time (sec) 180 210 240 270 300
High trace = normal upper limit OKY-T/10-W5, -T/16-W5
Output Voltage Calculated Rtrim (K)
Low trace - normal lower limit 3.160 6.947 11.780 15.004 23.077 41.973 80.021 (open)
3.3 V. 2.5 V. 2.0 V. 1.8 V. 1.5 V. 1.2 V. 1.0 V. 0.7525 V.
Resistor Trim Equation, W5 models: 21070 RTRIM (:) = _____________ - 5110 VOUT - 0.7525V
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 5 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
APPLICATION NOTES
Input Fusing Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. We recommend a time delay fuse installed in the ungrounded input supply line with a value which is approximately twice the maximum line current, calculated at the lowest input voltage. The installer must observe all relevant safety standards and regulations. For safety agency approvals, install the converter in compliance with the end-user safety standard, i.e. IEC/EN/UL 60950-1. Input Under-Voltage Shutdown and Start-Up Threshold Under normal start-up conditions, converters will not begin to regulate properly until the ramping-up input voltage exceeds and remains at the Start-Up Threshold Voltage (see Specifications). Once operating, converters will not turn off until the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent restart will not occur until the input voltage rises again above the Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a single input voltage. Users should be aware however of input sources near the Under-Voltage Shutdown whose voltage decays as input current is consumed (such as capacitor inputs), the converter shuts off and then restarts as the external capacitor recharges. Such situations could oscillate. To prevent this, make sure the operating input voltage is well above the UV Shutdown voltage AT ALL TIMES. Start-Up Time Assuming that the output current is set at the rated maximum, the Vin to Vout Start-Up Time (see Specifications) is the time interval between the point when the ramping input voltage crosses the Start-Up Threshold and the fully loaded regulated output voltage enters and remains within its specified accuracy band. Actual measured times will vary with input source impedance, external input capacitance, input voltage slew rate and final value of the input voltage as it appears at the converter. These converters include a soft start circuit to moderate the duty cycle of its PWM controller at power up, thereby limiting the input inrush current. The On/Off Remote Control interval from On command to Vout regulated assumes that the converter already has its input voltage stabilized above the Start-Up Threshold before the On command. The interval is measured from the On command until the output enters and remains within its specified accuracy band. The specification assumes that the output is fully loaded at maximum rated current. Similar conditions apply to the On to Vout regulated specification such as external load capacitance and soft start circuitry. Recommended Input Filtering The user must assure that the input source has low AC impedance to provide dynamic stability and that the input supply has little or no inductive content, including long distributed wiring to a remote power supply. The converter will operate with no additional external capacitance if these conditions are met.
For best performance, we recommend installing a low-ESR capacitor immediately adjacent to the converter's input terminals. The capacitor should be a ceramic type such as the Murata GRM32 series or a polymer type. Initial suggested capacitor values are 10 to 22 F, rated at twice the expected maximum input voltage. Make sure that the input terminals do not go below the undervoltage shutdown voltage at all times. More input bulk capacitance may be added in parallel (either electrolytic or tantalum) if needed. Recommended Output Filtering The converter will achieve its rated output ripple and noise with no additional external capacitor. However, the user may install more external output capacitance to reduce the ripple even further or for improved dynamic response. Again, use low-ESR ceramic (Murata GRM32 series) or polymer capacitors. Initial values of 10 to 47 F may be tried, either single or multiple capacitors in parallel. Mount these close to the converter. Measure the output ripple under your load conditions. Use only as much capacitance as required to achieve your ripple and noise objectives. Excessive capacitance can make step load recovery sluggish or possibly introduce instability. Do not exceed the maximum rated output capacitance listed in the specifications. Input Ripple Current and Output Noise All models in this converter series are tested and specified for input reflected ripple current and output noise using designated external input/output components, circuits and layout as shown in the figures below. In the figure below, the Cbus and Lbus components simulate a typical DC voltage bus. Please note that the values of Cin, Lbus and Cbus will vary according to the specific converter model.
TO OSCILLOSCOPE
CURRENT PROBE +INPUT LBUS CBUS CIN
VIN
+ - + -
-INPUT CIN = 2 x 100F, ESR < 700m @ 100kHz CBUS = 1000F, ESR < 100m @ 100kHz LBUS = 1H
Figure 4: Measuring Input Ripple Current
In figure 5, the two copper strips simulate real-world printed circuit impedances between the power supply and its load. In order to minimize circuit errors and standardize tests between units, scope measurements should be made using BNC connectors or the probe ground should not exceed one halfinch and soldered directly to the test circuit.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 6 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
CAUTION: If you routinely or accidentally exceed these Derating guidelines, the converter may have an unplanned Over Temperature shut down. Also, these graphs are all collected at slightly above Sea Level altitude. Be sure to reduce the derating for higher density altitude.
C2 SCOPE RLOAD
COPPER STRIP +OUTPUT
C1
-OUTPUT COPPER STRIP
Output Fusing The converter is extensively protected against current, voltage and temperature extremes. However your output application circuit may need additional protection. In the extremely unlikely event of output circuit failure, excessive voltage could be applied to your circuit. Consider using an appropriate fuse in series with the output. Output Current Limiting Current limiting inception is defined as the point at which full power falls below the rated tolerance. See the Performance/Functional Specifications. Note particularly that the output current may briefly rise above its rated value in normal operation as long as the average output power is not exceeded. This enhances reliability and continued operation of your application. If the output current is too high, the converter will enter the short circuit condition. Output Short Circuit Condition When a converter is in current-limit mode, the output voltage will drop as the output current demand increases. If the output voltage drops too low (approximately 98% of nominal output voltage for most models), the magnetically coupled voltage used to develop primary side voltages will also drop, thereby shutting down the PWM controller. Following a time-out period, the PWM will restart, causing the output voltage to begin ramping up to its appropriate value. If the short-circuit condition persists, another shutdown cycle will initiate. This rapid on/off cycling is called "hiccup mode". The hiccup cycling reduces the average output current, thereby preventing excessive internal temperatures and/or component damage. A short circuit can be tolerated indefinitely. The "hiccup" system differs from older latching short circuit systems because you do not have to power down the converter to make it restart. The system will automatically restore operation as soon as the short circuit condition is removed. Remote On/Off Control On the input side, a remote On/Off Control can be ordered with either polarity. Please refer to the Connection Diagram on page 1 for On/Off connections. Positive polarity models are enabled when the On/Off pin is left open or is pulled high to +Vin with respect to -Vin. Positive-polarity devices are disabled when the On/Off is grounded or brought to within a low voltage (see Specifications) with respect to -Vin. Negative polarity devices are on (enabled) when the On/Off pin is left open or brought to within a low voltage (see Specifications) with respect to -Vin. The device is off (disabled) when the On/Off is pulled high (see Specifications) with respect to -Vin.
C1 = 0.1F CERAMIC C2 = 10F TANTALUM LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 5: Measuring Output Ripple and Noise (PARD)
Minimum Output Loading Requirements All models regulate within specification and are stable under no load to full load conditions. Operation under no load might however slightly increase output ripple and noise. Thermal Shutdown To prevent many over temperature problems and damage, these converters include thermal shutdown circuitry. If environmental conditions cause the temperature of the DC/DC's to rise above the Operating Temperature Range up to the shutdown temperature, an on-board electronic temperature sensor will power down the unit. When the temperature decreases below the turn-on threshold, the converter will automatically restart. There is a small amount of hysteresis to prevent rapid on/off cycling. CAUTION: If you operate too close to the thermal limits, the converter may shut down suddenly without warning. Be sure to thoroughly test your application to avoid unplanned thermal shutdown. Temperature Derating Curves The graphs in the next section illustrate typical operation under a variety of conditions. The Derating curves show the maximum continuous ambient air temperature and decreasing maximum output current which is acceptable under increasing forced airflow measured in Linear Feet per Minute ("LFM"). Note that these are AVERAGE measurements. The converter will accept brief increases in current or reduced airflow as long as the average is not exceeded. Note that the temperatures are of the ambient airflow, not the converter itself which is obviously running at higher temperature than the outside air. Also note that very low flow rates (below about 25 LFM) are similar to "natural convection", that is, not using fan-forced airflow. Murata Power Solutions makes Characterization measurements in a closed cycle wind tunnel with calibrated airflow. We use both thermocouples and an infrared camera system to observe thermal performance.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 7 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Dynamic control of the On/Off function should be able to sink appropriate signal current when brought low and withstand appropriate voltage when brought high. Be aware too that there is a finite time in milliseconds (see Specifications) between the time of On/Off Control activation and stable, regulated output. This time will vary slightly with output load type and current and input conditions. Output Capacitive Load These converters do not require external capacitance added to achieve rated specifications. Users should only consider adding capacitance to reduce switching noise and/or to handle spike current load steps. Install only enough capacitance to achieve noise objectives. Excess external capacitance may cause regulation problems, degraded transient response and possible oscillation or instability. Remote Sense Input The Sense input is normally connected at the load for the respective Sense polarity (+Sense to the +Vout load). The sense input compensates for voltage drops along the output wiring such as moderate IR drops and the current carrying capacity of PC board etch. This output drop (the difference between Sense and Vout when measured at the converter) should not exceed 0.5V. Use heavier connections if this drop is excessive. The sense input also improves the stability of the converter and load system by optimizing the control loop phase margin. If the Sense function is not used for remote regulation, the user should connect the Sense to their respective Vout at the converter pins. Sense lines on the PCB should run adjacent to DC signals, preferably Ground. Any long, distributed wiring and/or significant inductance introduced into the Sense control loop can adversely affect overall system stability. If in doubt, test your applications by observing the converter's output transient response during step loads. There should not be any appreciable ringing or oscillation. Do not exceed maximum power ratings. Excessive voltage differences between Vout and Sense together with trim adjustment of the output can cause the overvoltage protection circuit to activate and shut down the output. Power derating of the converter is based on the combination of maximum output current and the highest output voltage at the ouput pins. Therefore the designer must insure: (Vout at pins) x (Iout) (Max. rated output power) Sequence/Tracking Input (Optional) After external input power is applied and the converter stabilizes, a high impedance Sequence/Tracking input pin accepts an external analog voltage referred to -Vin. The output power voltage will then track this Sequence/ Tracking input at a one-to-one ratio up to the nominal set point voltage for that converter. This Sequencing input may be ramped, delayed, stepped or otherwise phased as needed for the output power, all fully controlled by the user's external circuits. As a direct input to the converter's feedback loop, response to the Sequence/Tracking input is very fast (milliseconds). Operation To use the Sequence/Tracking pin after power start-up stabilizes, apply a rising external voltage to the Sequence/Tracking input. As the voltage rises, the output voltage will track the Sequence/Tracking input (gain = 1). The output voltage will stop rising when it reaches the normal set point for the converter. The Sequence/Tracking input may optionally continue to rise without any effect on the output. Keep the Sequence/Tracking input voltage below the converter's input supply voltage. Use a similar strategy on power down. The output voltage will stay constant until the Sequence/Tracking input falls below the set point. Guidelines for Sequence/Tracking Applications [1] Leave the converter's On/Off Enable control in the On setting. Normally, you should just leave the On/Off pin open. [2] Allow the converter to stabilize (typically less than 20 mS after +Vin power on) before raising the Sequence/Tracking input. Also, if you wish to have a ramped power down, leave +Vin powered all during the down ramp. Do not simply shut off power. [3] If you do not plan to use the Sequence/Tracking pin, leave it open. [4] Observe the Output slew rate relative to the Sequence/Tracking input. A rough guide is 2 Volts per millisecond maximum slew rate. If you exceed this slew rate on the Sequence/Tracking pin, the converter will simply ramp up at it's maximum output slew rate (and will not necessarily track the faster Sequence/Tracking input). The reason to carefully consider the slew rate limitation is in case you want two different POL's to precisely track each other. [5] Be aware of the input characteristics of the Sequence/Tracking pin. The high input impedance affects the time constant of any small external ramp capacitor. And the bias current will slowly charge up any external caps over time if they are not grounded. [6] Allow the converter to eventually achieve its full rated setpoint output voltage. Do not remain in ramp up/down mode indefinitely. The converter is characterized and meets all its specifications only at the setpoint voltage (plus or minus any trim voltage). [7] The Sequence/Tracking is a sensitive input into the feedback control loop of the converter. Avoid noise and long leads on this input. Keep all wiring very short. Use shielding if necessary. Pre-Biased Startup Some sections have external power already partially applied (possibly because of earlier power sequencing) before POL power up. Or leakage power is present so that the DC/DC converter must power up into an existing output voltage. This power may either be stored in an external bypass capacitor or supplied by an active source. These converters include a pre-bias startup mode to prevent initialization problems. This "pre-biased" condition can also occur with some types of programmable logic or because of blocking diode leakage or small currents passed through forward biased ESD diodes. This feature is variously called "monotonic" because the voltage does not decay or produce a negative transient once the input power is applied and startup begins. Sequence/Tracking operation is not available during pre-bias startup.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 8 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PERFORMANCE DATA AND OSCILLOGRAMS - OKY2-T/16-W5
Efficiency vs. Line Voltage and Load Current @ +25C (VOUT = 3.3V)
100
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=5V, Vout=3.3V, airflow direction is transverse)
16.50 16.25 16.00
95
15.75 15.50 Output Current (Amps)
Efficiency (%)
90
VIN = 4.5V VIN = 5V VIN = 5.5V
15.25 15.00 14.75 14.50 14.25 14.00 13.75 13.50 13.25 13.00
Natural convection 100 LFM 200 LFM 300 LFM 400 LFM
85
80
75 0 2 4 6 8 10 12 14 16
20
25
30
35
40
Load Curre nt (Amps)
45 50 55 60 65 Ambient Temperature (C)
70
75
80
85
90
Output Ripple and Noise (Vin=5V, Vout=3.3V, Iout=16A, Cload=0, ScopeBW=100MHz)
On/Off Enable Startup Delay (Vin=5V, Vout=3.3V, Iout=16A, Cload=0) Trace 2=Enable In, Trace 1=Vout
Step Load Transient Response (Vin=5V, Vout=3.3V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
Step Load Transient Response (Vin=5V, Vout=3.3V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
In this graphic data, 10 Amp models perform identically to 16 Amp models with the limitation of 10 Amps output.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 9 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PERFORMANCE DATA AND OSCILLOGRAMS - OKY2-T/16-W5
Efficiency vs. Line Voltage and Load Current @ +25C (VOUT = 2.5V)
100 95 90
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=5V, Vout=2.5V, airflow direction is transverse)
16.5 16 15.5
Efficiency (%)
80 75 70 65 60 55 50 0 2 4
VIN = 3V VIN = 5V VIN = 5.5V
Output Current (Amps)
85
15 14.5 14 13.5 13 12.5 20
Natural convection 100 LFM 200 LFM 300 LFM 400 LFM
6
8
10
12
14
16
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Load Curre nt (Amps)
Ambient Temperature (C)
Output Ripple and Noise (Vin=5V, Vout=2.5V, Iout=16A, Cload=0, ScopeBW=100MHz)
On/Off Enable Startup Delay (Vin=5V, Vout=2.5V, Iout=16A, Cload=0) Trace 2=Enable In, Trace 1=Vout
Step Load Transient Response (Vin=5V, Vout=2.5V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
Step Load Transient Response (Vin=5V, Vout=2.5V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 10 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PERFORMANCE DATA AND OSCILLOGRAMS - OKY2-T/16-W5
Efficiency vs. Line Voltage and Load Current @ +25C (VOUT = 1.8V)
100 95 90 VIN = 3V VIN = 5V VIN = 5.5V
Output Current (Amps)
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=5V, Vout=1.8V, airflow direction is transverse)
16.50 16.25 16.00 15.75 15.50 15.25 15.00 14.75 14.50 14.25 Natural convection 100 LFM 200 LFM 300 LFM 400 LFM
85 Efficiency (%) 80 75 70 65 60 55 50 0 2 4
6
8
10
12
14
16
14.00 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Ambient Temperature (C)
Load Curre nt (Amps)
Output Ripple and Noise (Vin=5V, Vout=1.8V, Iout=16A, Cload=0, ScopeBW=100MHz)
On/Off Enable Startup Delay (Vin=5V, Vout=1.8V, Iout=16A, Cload=0) Trace 2=Enable In, Trace 1=Vout
Step Load Transient Response (Vin=5V, Vout=1.8V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
Step Load Transient Response (Vin=5V, Vout=1.8V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 11 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PERFORMANCE DATA AND OSCILLOGRAMS - OKY2-T/16-W5
Efficiency vs. Line Voltage and Load Current @ +25C (VOUT = 1.5V)
100 95 90 85 Efficiency (%) 80 75 70 65 60 55 50 0 2 4 6 8 10 12 14 16 Load Curre nt (Amps) VIN = 3V VIN = 5V VIN = 5.5V
Output Ripple and Noise (Vin=5V, Vout=1.5V, Iout=16A, Cload=0, ScopeBW=100MHz)
On/Off Enable Startup Delay (Vin=5V, Vout=1.5V, Iout=16A, Cload=0) Trace 2=Enable In, Trace 1=Vout
Step Load Transient Response (Vin=5V, Vout=1.5V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
Step Load Transient Response (Vin=5V, Vout=1.5V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 12 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PERFORMANCE DATA AND OSCILLOGRAMS - OKY2-T/16-W5
Efficiency vs. Line Voltage and Load Current @ +25C (VOUT = 1.2V)
95 90 85 VIN = 3V VIN = 5V VIN = 5.5V
Output Current (Amps) 16.50 16.25 16.00 15.75 15.50 15.25 15.00 14.75 14.50 14.25 Natural convection 100 LFM 200 LFM 300 LFM, 400 LFM
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=5V, Vout=1.2V, airflow direction is transverse)
80 Efficiency (%) 75 70 65 60 55 50 45 0 2 4
6
8
10
12
14
16
14.00 20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Load Curre nt (Amps)
Ambient Temperature (C)
Output Ripple and Noise (Vin=5V, Vout=1.2V, Iout=16A, Cload=0, ScopeBW=100MHz)
On/Off Enable Startup Delay (Vin=5V, Vout=1.2V, Iout=16A, Cload=0) Trace 2=Enable In, Trace 1=Vout
Step Load Transient Response (Vin=5V, Vout=1.2V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
Step Load Transient Response (Vin=5V, Vout=1.2V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 13 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PERFORMANCE DATA AND OSCILLOGRAMS - OKY2-T/16-W5
Efficiency vs. Line Voltage and Load Current @ +25C (VOUT = .75V)
95 90 85
Output Current (Amps) 16.25 16.00 15.75
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=5V, Vout=0.75V, airflow direction is transverse)
80 Efficiency (%) 75 70 65 60 55 50 45 0 2 4
VIN = 3V VIN = 5V VIN = 5.5V
15.50 15.25 15.00 14.75 14.50 14.25 14.00 20
Natural convection 100, 200, 300, 400 LFM
6
8
10
12
14
16
25
30
35
40
Load Curre nt (Amps)
45 50 55 60 65 Ambient Temperature (C)
70
75
80
85
90
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=3.3V, Vout=2.5V, airflow direction is transverse)
16.25 16 15.75 15.5
Output Current (Amps) Output Current (Amps)
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=3.3V, Vout=1.8V, airflow direction is transverse)
16.50 16.25 16.00 15.75 15.50 15.25 15.00 14.75 14.50 14.25 14.00 13.75 13.50 13.25 13.00 Natural convection 100 LFM 200 LFM 300 LFM 400 LFM
15.25 15 14.75 14.5 14.25 14 13.75 13.5 13.25 13 20 25 30 35 40
Natural convection 100 LFM 200 LFM 300 LFM 400 LFM
45
50 55 60 65 Ambient Temperature (C)
70
75
80
85
90
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Ambient Temperature (C)
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=3.3V, Vout=1.2V, airflow direction is transverse)
16.50 16.25 16.00
Output Current (Amps) Output Current (Amps)
Maximum Current Temperature Derating vs. Airflow at sea level (Vin=3.3V, Vout=0.75V, airflow direction is transverse)
16.20 16.00 15.80 Natural convection 100 LFM 200 LFM 300 LFM 400 LFM
15.75 15.50 15.25 15.00 14.75 14.50 14.25 14.00 20 25 30 35 40 45 50 55 60 65 Ambient Temperature (C) 70 75 80 85 90 Natural convection 100 LFM 200 LFM 300 LFM 400 LFM
15.60 15.40 15.20 15.00 14.80 14.60 14.40 20
25
30
35
40
45 50 55 60 65 Ambient Temperature (C)
70
75
80
85
90
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 14 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
PERFORMANCE DATA AND OSCILLOGRAMS - OKY2-T/16-W5
Output Ripple and Noise (Vin=5V, Vout=0.75V, Iout=16A, Cload=0, ScopeBW=100MHz) On/Off Enable Startup Delay (Vin=5V, Vout=0.75V, Iout=16A, Cload=0) Trace 2=Enable In, Trace 1=Vout
Step Load Transient Response (Vin=5V, Vout=0.75V, Cload=0, Iout=8A to 16A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
Step Load Transient Response (Vin=5V, Vout=0.75V, Cload=0, Iout=16A to 8A) Trace 1=Vout, 100 mV/div. Trace 4=Iout, 5A/div.
Product Label Because of the small size of these products, the product label contains a character-reduced code to indicate the model number and manufacturing date code. Not all items on the label are always used. Please note that the label differs from the product photograph. Here is the layout of the label:
Model Number OKY-T/10-W5P-C OKY-T/10-W5N-C OKY2-T/10-W5P-C OKY2-T/10-W5N-C OKY-T/16-W5P-C OKY-T/16-W5N-C OKY2-T/16-W5P-C OKY2-T/16-W5N-C
Product Code Y01010 Y00010 Y21010 Y20010 Y01016 Y00016 Y21016 Y20016
Mfg. date code
Y01110 YMDX Rev.
Product code Revision level
Figure 2. Label Artwork Layout
The manufacturing date code is four characters: First character - Last digit of manufacturing year, example 2009 Second character - Month code (1 through 9 and O through D) Third character - Day code (1 through 9 = 1 to 9, 10=O and 11 through 31 = A through Z) Fourth character - Manufacturing information
The label contains three rows of information: First row - Murata Power Solutions logo Second row - Model number product code (see table) Third row - Manufacturing date code and revision level
www.murata-ps.com
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 15 of 16
OKY-T/10 & T/16-W5 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
TAPE & REEL IMFORMATION
FEED (UNWIND) DIRECTION ------2.00 .079 (P/U) 18.19 .716 (P/U) 40.40 1.591 9.14 .360 4.00 .157
PIN #1
ROUND HOLES 1.75 .069
44.00 1.732
2.00 .079
24.00 .945
KEY IN POCKET
OBLONG HOLES
TOP COVER TAPE
THIRD ANGLE PROJECTION
.53 REF
101.6 4.00 (CORE)
44.0 1.73 REF
PIN #1 THIS CORNER (FARSIDE)
.50
PICKUP NOZZLE LOCATION ( 3-6mm)
1.30 REF
330.2 13.00
13.00 .512
.27
REEL INFORMATION (250 UNITS PER REEL)
PICK & PLACE PICKUP (P/U)
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2010 Murata Power Solutions, Inc.
www.murata-ps.com/locations
22 Mar 2010
email: sales@murata-ps.com
MDC_OKY_T10T16.W5.A03 Page 16 of 16


▲Up To Search▲   

 
Price & Availability of OKY-T1010

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X